Hepatitis C Virus (HCV) by Quantitative PCR

Specimen Container

3 Lav

Specimen Collection Type

Serum

Minimum Volume To Collect (Ml)

4 mL

Pediatric Volume To Collect (Ml)

4 mL

Specimen Preparation

Centrifuge and separate plasma <24H

Stability

Ambient Stability: 24 hrs
Refrig Stability: 6 Days
Frozen Stability: 12 Weeks

Unacceptable Conditions

Plasma or serum on red cells greater than 24 hours

Preferred Transportation Temperature

REFRIGERATED

Performed

Tuesday, Friday

Reported

Next day
Positive specimens are sent to ARUP for genotyping

Methodology

Reverse Transcription, Quantitative Real-Time PCR, Sequencing

Lab Department

Core

Testing Location

IHC

Synonyms

HCV Genotype
Hepatitis C Viral Load with Reflex to Genotype
HCV RNA Quantitative
HCV Quant
HCV Viral Load
HCV Quantitation
HCV RNA
Hep C Genotype
Hepatitis C Genotype
HCV Treatment Decision
HCV PCR
Hepatitis C Viral Load, Genotype Reflex
Nucleic Acid Amplification Test (NAAT)
Viral Load Monitoring

Test OR Panel

Test

AOE

IsPregnant

Misc Instructions

SPECIMEN PREPARATION: 1.7 mL plasma or serum
(800 uL is the absolute minimum required volume for initial testing. If the sample requires reflex to genotyping, 800 uL will not be sufficient and the patient will need to be recollected

Unit of Measurement

IU/mL

CPT Codes

87522

LOINC

11011-4

Streamlined Online Payments

Simplify payments with our user-friendly online system. Quick, secure, and hassle-free. Experience convenience with every click.

Instant Confirmation, Every Time

Receive instant payment confirmations for peace of mind. Swift transactions, reliable updates. Elevate your payment experience with us.

24 / 7 Payment Access

Access our online payment portal anytime, anywhere. Your bills, your schedule. Experience the freedom of 24/7 payment convenience.